Bio-Medical Waste (Management and Handling) Rules, 1998 - Schedule V

Email Print This Page bookmark
Font : A-A+

SCHEDULE V
(see Rule 5 and Schedule 1)

STANDARDS FOR TREATMENT AND DISPOSAL OF BIO-MEDICAL WASTES

STANDARDS FOR INCINERATORS:

All incinerators shall meet the following operating and emission standards

A. Operating Standards

1. Combustion efficiency (CE) shall be at least 99.00%.

2. The Combustion efficiency is computed as follows:

%C02
C.E. = ------------ X 100
%C02 + % CO

3. The temperature of the primary chamber shall be 800 50 deg. C.

4. The secondary chamber gas residence time shall be at least I (one) second at 1050 50 C, with minimum 3% Oxygen in the stack gas.

B. Emission Standards

Parameters Concentration mg/Nm3 at (12% CO2 correction)

(1) Particulate matter 150
(2) Nitrogen Oxides 450
(3) HCI 50
(4) Minimum stack height shall be 30 metres above ground
(5) Volatile organic compounds in ash shall not be more than 0.01%

Note:

Suitably designed pollution control devices should be installed/retrofitted with the incinerator to achieve the above emission limits, if necessary.

Wastes to be incinerated shall not be chemically treated with any chlorinated disinfectants.

Chlorinated plastics shall not be incinerated.

Toxic metals in incineration ash shall be limited within the regulatory quantities as defined under the Hazardous Waste (Management and Handling Rules,) 1989.

Only low sulphur fuel like L.D.0dLS.H.S.1Diesel shall be used as fuel in the incinerator.

STANDARDS FOR WASTE AUTOCLAVING:

The autoclave should be dedicated for the purposes of disinfecting and treating bio-medical waste,

(I) When operating a gravity flow autoclave, medical waste shall be subjected to :

(i) a temperature of not less than 121 C and pressure of 15 pounds per square inch (psi) for an autoclave residence time of not less than 60 minutes; or

(ii) a temperature of not less than 135 C and a pressure of 31 psi for an autoclave residence time of not less than 45 minutes; or

(iii) a temperature of not less than 149 C and a pressure of 52 psi for an autoclave residence time of not less than 30 minutes.

(II) When operating a vacuum autoclave, medical waste shall be subjected to a minimum of one pre-vacuum pulse to purge the autoclave of all air. The waste shall be subjected to the following:

(i) a temperature of not less than 121 C and pressure of 15 psi per an autoclave residence time of not less than 45 minutes; or

(ii) a temperature of not less than 135 C and a pressure of 31 psi for an autoclave residence time of not less than 30 minutes;

(III) Medical waste shall not be considered properly treated unless the time, temperature and pressure indicators indicate that the required time, temperature and pressure were reached during the autoclave process. If for any reasons, time temperature or pressure indicator indicates that the required temperature, pressure or residence time was not reached, the entire load of medical waste must be autoclaved again until the proper temperature, pressure and residence time were achieved.

(IV) Recording of operational parameters

Each autoclave shall have graphic or computer recording devices which will automatically and continuously monitor and record dates, time of day, load identification number and operating parameters throughout the entire length of the autoclave cycle.

(V) Validation test

Spore testing :

The autoclave should completely and consistently kill the approved biological indicator at the maximum design capacity of each autoclave unit. Biological indicator for autoclave shall be Bacillus stearothermophilus spores using vials or spore Strips; with at least 1X104 spores per millilitre. Under no circumstances will an autoclave have minimum operating parameters less than a residence time of 30 minutes, regardless of temperature and pressure, a temperature less than 121 C or a pressure less than 15 psi.

(VI) Routine Test

A chemical indicator strip/tape the changes colour when a certain temperature is reached can be used to verify that a specific temperature has been achieved. It may be necessary to use more than one strip over the waste package at different location to ensure that the inner content of the package has been adequately autoclaved

STANDARD FOR LIQUID WASTE:

The effluent generated from the hospital should conform to the following limits

PARAMETERS PERMISSIBLE LIMITS

PH 63-9.0
Susponded solids 100 mg/l
Oil and grease 10 mg/l
BOD 30 mg/l
COD 250 mg/l
Bio-assay test 90% survival of fish after 96 hours in 100% effluent.

These limits are applicable to those, hospitals which are either connected with sewers without terminal sewage treatment plant or not connected to public sewers. For discharge into public sewers with terminal facilities, the general standards as notified under the Environment (Protection) Act, 1986 shall be applicable.

STANDARDS OF MICROWAVING

1 Microwave treatment shall not be used for cytotoxic, hazardous or radioactive wastes, contaminated animal car casses, body parts and large metal items.

2. The microwave system shall comply with the efficacy test/routine tests and a performance guarantee may be provided by the supplier before operation of the limit.

3. The microwave should completely and consistently kill the bacteria and other pathogenic organisms that is ensured by approved biological indicator at the maximum design capacity of each microwave unit. Biological indicators for microwave shall be Bacillus Subtilis spores using vials or spore strips with at least 1 x 101 spores per milliliter.

STANDARDS FOR DEEP BURIAL

1. A pit or trench should he dug about 2 meters deep. It should be half filled with waste, then covered with lime within 50 cm of the surface, before filling the rest of the pit with soil.

2. It must be ensured that animals do not have any access to burial sites. Covers of galvanised iron/wire meshes may be used.

3. On each occasion, when wastes are added to the pit, a layer of 10 em of soil shall be added to cover the wastes.

4. Burial must be performed under close and dedicated supervision.

5. The deep burial site should be relatively impermeable and no shallow well should be close to the site.

6. The pits should be distant from habitation, and sited so as to ensure that no contamination occurs of any surface water or ground water. The area should not be prone to flooding or erosion.

7. The location of the deep burial site will be authorised by the prescribed authority.

8. The institution shall maintain a record of all pits for deep burial.

 
 

Post a Comment

Comments should be on the topic and should not be abusive. The editorial team reserves the right to review and moderate the comments posted on the site.
Notify me when reply is posted
I agree to the terms and conditions
drnilesh18sanap 

can you please guide me where should i approach in case of practising at interior place with no local authority support....what should i do in tht case?

drvardhini 

Is each hospital or clinic stick to these rules? Is the public protected? Each hospital or clinic must have the yearly inspection certificate duly signed by the officer incharge of bio-waste management. violation must lead to closure of that hospital or clinic.

pramodreddy 

If the waste collection and treatment is to be handled by a private institution, then what are the rules or procedures to be followed including acquiring of land (how should the surroundings be)

Drameetsoni 

Is it compulsary to keep the bio waste in freezers at the place of generation if the bio waste is taken from there to the disposal facility on daily bases?
If required tostore for more than 48 hours than what is the optimum tempreture at which it should be stored?
What is the optional treatment for needles and sharps to follw in stead of cutting or burning?

prava 

i m a student of hospital managent so its really important for me to know everything regarding this and i have also seen that nowdays hospitals r getting really srious regarding this.

Medindia Newsletters

Subscribe to our Free Newsletters!

Terms & Conditions and Privacy Policy.

Find a Doctor

Stay Connected

  • Available on the Android Market
  • Available on the App Store